inquiry
Leave Your Message
China ECI-500 Ovulation Detector for Estrus Detection in Pigs, Sheep, Cows, Dogs - Suppliers and Factory Direct Offer
Hot Products

China ECI-500 Ovulation Detector for Estrus Detection in Pigs, Sheep, Cows, Dogs - Suppliers and Factory Direct Offer

Experience the superior quality of our product, designed using advanced German technology, ensuring both safety and efficiency for users. With an impressive waterproof level of IPX7, this product is reliable and durable, making it perfect for your needs. The safe bio-silicone probe adds an extra layer of comfort and security in usage. Additionally, the replaceable battery feature ensures long-term use without worry. As a leading factory in China, we take pride in supplying high-quality products to meet your demands. Choose us as your trusted suppliers for innovative solutions!

    Description

    One of the most important elements of livestock breeding management is the detection of the ovulatory cycle, this is because the effectiveness of female insemination is closely related to the precise timing of insemination.

    Studies have shown that the rate of missed detection of the ovulatory cycle in breeding practices is very high. Because estrus usually occurs irregularly in real time and has a short cycle time, it is easy to miss the timing of estrus with few or careless observations.

    Therefore, biotechnological methods for detecting estrus in various females have been investigated, one of which is the measurement of the electrical resistance of vaginal mucus during estrus. It was shown that there is also a close relationship between changes in vaginal mucus resistance and hormone levels. An ovulation detector was designed utilizing the above phenomenon.

    ECI-500 Veterinary ovulation detector-detail 1
    ECI-500 Veterinary ovulation detector-detail 3

    Using video

    Parameter

    Type ECI-500
    Probing rod Pig: 300mm
    Sheep: 200mm
    Cow: 425mm
    Dog: 120mm
    Operating temp. 0-50℃
    Working humidity 85%
    Main material ABS
    Probe material Bio-silicone
    Battery 9V6F22
    Accuracy ±1%
    Screen 3.5-inch
    N.W. 360g
    Reference value Ovulating Not ovulating
    Pig 250(±10) >450
    Cow 210(±10) >400
    Sheep 420(±10) >600
    Dog ≥200 <200

    The role of the ovulation detector

    • Determining the timing of mating in animals without regular estrus
    • Detecting the timing of asymptomatic estrus
    • Improving the effectiveness of artificial insemination
    • Improving the economic efficiency of farms
    ECI-500 Veterinary ovulation detector-detail 2
    ECI-500 Veterinary ovulation detector-detail 4

    Ovulation Detector Procedure

    1
    The animal's vulva was opened and a sterilized probe was carefully inserted into the vagina.
    2
    Taking care to insert the probe at a 45-degree angle from the bottom up to avoid inserting the probe into the urethra.
    3
    Ovulation detector is inserted further until resistance is felt such that the end of the probe with two electrodes is placed at the end of the animal's vagina, at the cervical canal. The probe is then rotated 1 turn to achieve optimal contact of the electrodes with the mucus. (Note: The depth of probe insertion depends on the length of the vagina and may vary from animal to animal, so insertion of the probe should always be followed until resistance is felt.)
    4
    Pressing the switch for measurement, press the switch once at an interval of 3 seconds, press three times for three measurements, and press the button again to display the measured value.
    5
    After measurement, long press the switch for shutdown or 30 seconds without operation automatically shutdown.
    ECI-500 Veterinary ovulation detector-detail 5 animal
    ECI-500 Veterinary ovulation detector-detail 6 application

    Frequently Asked Questions

    How does the ECI-500 Veterinary Ovulation Detector determine the timing of estrus?
    The device measures the electrical resistance of the animal's vaginal mucus, which changes in close relationship with hormone levels during the ovulatory cycle. This allows breeders to identify the optimal window for insemination.
    What are the probe lengths available for different livestock?
    The probing rods are designed to suit specific animals: 300mm for pigs, 200mm for sheep, 425mm for cows, and 120mm for dogs.
    What materials are used to construct the device and the probe?
    The main body of the ECI-500 is made of high-quality ABS material, while the probe rod uses bio-silicone to ensure safety and hygiene during animal testing.
    What are the reference values for identifying ovulation in pigs and cows?
    For pigs, the ovulating reference value is 250(±10) and not ovulating is >450. For cows, the ovulating reference value is 210(±10) and not ovulating is >400.
    How should the probe be inserted safely during testing?
    The sterilized probe should be inserted carefully at a 45-degree angle from the bottom up to avoid entering the urethra. Push it forward until resistance is felt at the cervical canal, then rotate the probe 1 full turn for optimal contact.
    How is the measurement process executed and displayed?
    Press the switch once at 3-second intervals for a total of three times to take three measurements. Press the button again to display the final measured value on the screen. The device will automatically shut down after 30 seconds of inactivity.