China ECI-X7H Veterinary Ultrasound Machine with OPU Probe - 256 Crystal Doppler, Touch Screen, Suppliers & Factory
Introducing our advanced veterinary ultrasound machine, featuring 256 crystal and 96 channel color Doppler technology. This cutting-edge device is designed for precision diagnostics in veterinary practices, ensuring accurate imaging and assessment. The user-friendly 10.1-inch HD touch screen provides clear visuals and easy navigation, making it an ideal choice for veterinarians, Included with the ultrasound machine are essential vacuum pump accessories: a wireless pedal for convenient operation, a reliable power supply, power cable, and a durable tube. Sourced from reputable suppliers in China, this veterinary ultrasound machine is manufactured in our state-of-the-art factory, ensuring high quality and durability for all veterinary needs. Enhance your practice with our premium ultrasound technology today!
ECI-X7H color Doppler Veterinary ultrasound machine for Ovum Pick-up supports in vivo egg collection and embryo transfer with precise guidance, which enhances the efficiency of genetic improvement and animal welfare, and adapts to the needs of modern animal husbandry. The Doppler color imaging technology of ECI-X7H veterinary ultrasound machine can display blood flow signals in real time, assisting in avoiding vascular areas and reducing the risk of bleeding during egg collection. 96-channel 256-crystal OPU ultrasound probe ensures a clear image, and compared with the traditional blind harvesting method, the use of effectively reduces ovarian damage and animal stress.
Using video
Parameter of Veterinary Ultrasound machine and vacuum pump
Working voltage: 200-240VAC
Working frequency: 50-60Hz
Rated power: 120VA
Working temperature: -20-50℃
Relative Humidity: 20-75%RH
Temperature setting range: 35.0-40.0℃.
Default temperature: 37.0℃
Temperature +/-: ±0.1℃
Temperature accuracy: ±0.5℃
Negative pressure range: 0-200mmHg
Recommended operating negative pressure: 60-150mmHg
Negative pressure error: ±5mmHg
Max. negative pressure: ≥500mmHg
No. of test tube wells: 8pcs
Weight: 8.38Kg
Size: 310*260*150mm
Operation of Vacuum Pump
1
Before switching on the OPU machine, please use the matching gas tube to connect, make sure the gas line is connected correctly, and confirm the connection is tight. As shown in the picture below: (The thick tube is made of silicone tube with an inner diameter of 4mm, and the thin tube is made of silicone tube with an inner diameter of 1.8mm; tube A is an empty bottle, and it is recommended that the liquid in tube B should not be more than 30mL, so as not to let the liquid enter into the main unit when there is a high negative pressure). Connect the power and switch on, and observe whether the LCD screen is displayed normally. The default temperature is 37.0 ℃, if necessary, you can through the ‘↑’, ‘↓’ to set the temperature by yourself. After switching on the thermostat tank heating system automatically heated into the working state.
2
Adjust the negative pressure setting knob to set the appropriate negative pressure value according to the actual operational needs. The negative pressure value increases with the clockwise pointer and decreases with the anti-clockwise pointer (the negative pressure value setting range is 0-200mmHg).
3
Thermostat tank heating stability (the actual temperature and the set temperature error of less than ± 0.5 ℃) can step on the white wireless foot switch or lightly press the start / pressurisation button, the instrument beeping sound prompts, the indicator light, the negative pressure system began to run. Please observe that the difference between the real-time negative pressure value and the set negative pressure value of the liquid crystal is less than ±5mmHg, and then the egg collection operation will start. Step on the white foot switch again or short press the start button, the system stops working.
4
In practice, the knob can be adjusted at any time to change the size of the negative pressure setting as required. If necessary, a thermometer is used to measure the temperature inside the collection tube placed in the thermostat tank at the same time. Egg collection can be performed when the temperature is within the required range (36-38°C).
5
If the line is blocked, step on the yellow foot switch or long press the boost button (more than 3 seconds). The negative pressure pump will generate maximum pumping force to relieve the oocyte fluid from clogging the line. Step on the yellow foot switch again or press the boost button briefly to stop.
Note: Liquid should be prevented from entering the inside of the main unit and damaging the air pump.
6
Test tubes containing oocyte fluid should be placed on the thermostat test tube rack in a timely manner, and the vacuum pump can place eight test tubes at the same time.
7
After the operation is finished, step on the white foot switch or short press the start button to stop the vacuum pump. Then close the switch at the back of the instrument after checking the normal status of the instrument.
Frequently Asked Questions
What are the primary applications of the ECI-X7H veterinary ultrasound machine?
The ECI-X7H is designed for Ovum Pick-up (OPU), supporting in vivo egg collection and embryo transfer with precise guidance to enhance genetic improvement and animal welfare.
How does Doppler color imaging technology help during egg collection?
It displays blood flow signals in real time, which helps the operator avoid vascular areas and significantly reduces the risk of bleeding during the procedure.
What are the specifications of the ECI-X7H OPU ultrasound probe?
The machine features a 96-channel, 256-crystal OPU probe with a frequency range of 5.0-8.0MHz and a scanning depth of 2-100mm, ensuring clear images and reducing ovarian damage.
What is the recommended operating negative pressure for the vacuum pump?
The negative pressure range of the pump is 0-200mmHg, with a recommended operating negative pressure of 60-150mmHg for optimal performance.
How many test tubes can be placed on the thermostat rack at once?
The thermostat test tube rack on the vacuum pump can accommodate up to 8 test tubes simultaneously.
What should be done if the fluid line becomes blocked during operation?
You can step on the yellow foot switch or long-press the boost button for more than 3 seconds. The pump will generate maximum pumping force to clear the clog from the line.