Discover our advanced veterinary ultrasound machine, featuring 256 crystal technology and a 96 channel color Doppler system. This high-quality ultrasound device comes equipped with a user-friendly 10.1 HD touch screen for seamless operation. As a trusted supplier in China, we ensure our products meet the highest standards in the industry. The complete package includes essential vacuum pump accessories: a wireless pedal, power supply, power cable, and tube. Partner with our factory for reliable veterinary solutions that enhance animal healthcare

    Veterinary Ultrasound machine for OPU

    ECI-X7H color Doppler Veterinary ultrasound machine for Ovum Pick-up supports in vivo egg collection and embryo transfer with precise guidance, which enhances the efficiency of genetic improvement and animal welfare, and adapts to the needs of modern animal husbandry. The Doppler color imaging technology of ECI-X7H veterinary ultrasound machine can display blood flow signals in real time, assisting in avoiding vascular areas and reducing the risk of bleeding during egg collection. 96-channel 256-crystal OPU ultrasound probe ensures a clear image, and compared with the traditional blind harvesting method, the use of effectively reduces ovarian damage and animal stress.
    ECI-X7H Portable Veterinary Ultrasound Scanner-detail 1

    Using video

    Parameter of Veterinary Ultrasound machine and vacuum pump

    Type

    ECI-X7H

    Color Doppler Veterinary Ultrasound Machine

    Ovum Pick-up Vacuum Pump

    Probe: 6.5MHz OPU probe

    R9

    256 elements

    5.0-8.0MHz

    2-100mm

    Display: 10-inch 1920*1080

    Frequency: 3.5~7.5MHz

    Mode: B, C, PW

    Cine-loop: 30~300s

    Storage: 64G

    Channel: 32

    Measurement: Back-fat thickness, Loin-eye muscle area, Perimeter, Diameter, Angle

    Dead zone: ≤1mm

    Gain: adjustable

    Interface: USB, HDMI

    Size:330*210*35mm

    Weight: 3kg

    Working voltage: 200-240VAC

    Working frequency: 50-60Hz

    Rated power: 120VA

    Working temperature: -20-50℃

    Relative Humidity: 20-75%RH

    Temperature setting range: 35.0-40.0℃.

    Default temperature: 37.0℃

    Temperature +/-: ±0.1℃

    Temperature accuracy: ±0.5℃

    Negative pressure range: 0-200mmHg

    Recommended operating negative pressure: 60-150mmHg

    Negative pressure error: ±5mmHg

    Max. negative pressure: ≥500mmHg

    No. of test tube wells: 8pcs

    Weight: 8.38Kg

    Size: 310*260*150mm

    Operation of Vacuum Pump

    1
    Before switching on the OPU machine, please use the matching gas tube to connect, make sure the gas line is connected correctly, and confirm the connection is tight. As shown in the picture below: (The thick tube is made of silicone tube with an inner diameter of 4mm, and the thin tube is made of silicone tube with an inner diameter of 1.8mm; tube A is an empty bottle, and it is recommended that the liquid in tube B should not be more than 30mL, so as not to let the liquid enter into the main unit when there is a high negative pressure).Connect the power and switch on, and observe whether the LCD screen is displayed normally. The default temperature is 37.0 ℃, if necessary, you can through the ‘↑’, ‘↓’ to set the temperature by yourself. After switching on the thermostat tank heating system automatically heated into the working state.
    product-description1
    2
    Adjust the negative pressure setting knob to set the appropriate negative pressure value according to the actual operational needs. The negative pressure value increases with the clockwise pointer and decreases with the anti-clockwise pointer (the negative pressure value setting range is 0-200mmHg).
    3
    Thermostat tank heating stability (the actual temperature and the set temperature error of less than ± 0.5 ℃) can step on the white wireless foot switch or lightly press the start / pressurisation button, the instrument beeping sound prompts, the indicator light, the negative pressure system began to run. Please observe that the difference between the real-time negative pressure value and the set negative pressure value of the liquid crystal is less than ±5mmHg, and then the egg collection operation will start. Step on the white foot switch again or short press the start button, the system stops working.
    4
    In practice, the knob can be adjusted at any time to change the size of the negative pressure setting as required. If necessary, a thermometer is used to measure the temperature inside the collection tube placed in the thermostat tank at the same time. Egg collection can be performed when the temperature is within the required range (36-38°C).
    5
    If the line is blocked, step on the yellow foot switch or long press the boost button (more than 3 seconds). The negative pressure pump will generate maximum pumping force to relieve the oocyte fluid from clogging the line. Step on the yellow foot switch again or press the boost button briefly to stop.
    Note: Liquid should be prevented from entering the inside of the main unit and damaging the air pump.
    6
    Test tubes containing oocyte fluid should be placed on the thermostat test tube rack in a timely manner, and the vacuum pump can place eight test tubes at the same time.
    7
    After the operation is finished, step on the white foot switch or short press the start button to stop the vacuum pump. Then close the switch at the back of the instrument after checking the normal status of the instrument.
    ECI-X7H Portable Veterinary Ultrasound Scanner-detail 2ECI-X7H Portable Veterinary Ultrasound Scanner-detail 5 applicationECI-X7H Portable Veterinary Ultrasound Scanner-detail 3 applicationECI-X7H Portable Veterinary Ultrasound Scanner-detail 4 application
    Frequently Asked Questions (FAQ)
    What is the primary function of the ECI-X7H veterinary ultrasound machine?
    The ECI-X7H is designed for Ovum Pick-up (OPU) in animals. It supports in vivo egg collection and embryo transfer with precise ultrasonic guidance to improve genetic efficiency and animal welfare.
    How does Doppler color imaging improve the safety of the OPU procedure?
    The Doppler color imaging technology displays real-time blood flow signals, helping operators avoid vascular areas and significantly reducing the risk of bleeding during egg collection.
    What are the specifications of the OPU probe used with the ECI-X7H?
    The system utilizes a 96-channel, 256-crystal 6.5MHz OPU probe (R9) with a frequency range of 5.0-8.0MHz, which provides clear imaging and minimizes ovarian damage and animal stress.
    What is the recommended negative pressure range for the OPU vacuum pump?
    The vacuum pump features a negative pressure range of 0-200mmHg, with a recommended operating pressure range of 60-150mmHg for standard egg collection procedures.
    What temperature range should be maintained during egg collection?
    The vacuum pump thermostat tank has a temperature range of 35.0-40.0°C (defaulting to 37.0°C). Egg collection should ideally be performed when the collection tube temperature is stabilized between 36°C and 38°C.
    How do you resolve a line blockage during operation?
    If the line becomes blocked with oocyte fluid, you can step on the yellow foot switch or long press the boost button for more than 3 seconds. This prompts the pump to generate maximum suction to clear the blockage.