Introducing our advanced product featuring cutting-edge German technology, designed for safety and efficiency. This device is built to withstand harsh conditions with an impressive waterproof level of IPX7, ensuring it remains reliable and durable for long-term use. The safe bio-silicone probe enhances user experience while maintaining high standards of safety. Plus, the replaceable battery adds to the convenience, making it an ideal choice for users. As a leading China supplier and factory, we are committed to providing high-quality products that meet your needs

    Description
    One of the most important elements of livestock breeding management is the detection of the ovulatory cycle, this is because the effectiveness of female insemination is closely related to the precise timing of insemination.
    Studies have shown that the rate of missed detection of the ovulatory cycle in breeding practices is very high. Because estrus usually occurs irregularly in real time and has a short cycle time, it is easy to miss the timing of estrus with few or careless observations.
    Therefore, biotechnological methods for detecting estrus in various females have been investigated, one of which is the measurement of the electrical resistance of vaginal mucus during estrus. It was shown that there is also a close relationship between changes in vaginal mucus resistance and hormone levels. An ovulation detector was designed utilizing the above phenomenon.
    ECI-500 Veterinary ovulation detector-detail 1
    ECI-500 Veterinary ovulation detector-detail 3
    Using video
    Parameter

    Type

    ECI-500

    Probing rod

    Pig: 300mm

    Sheep: 200mm

    Cow: 425mm

    Dog: 120mm

    Operating temp.

    0-50℃

    Working humidity

    85%

    Main material

    ABS

    Probe material

    Bio-silicone

    Battery

    9V6F22

    Accuracy

    ±1%

    Screen

    3.5-inch

    N.W.

    360g

    Reference value

    Ovulating

    Not ovulating

    Pig

    250(±10)

    >450

    Cow

    210(±10)

    >400

    Sheep

    420(±10)

    >600

    Dog

    ≥200

    <200

    The role of the ovulation detector
    • Determining the timing of mating in animals without regular estrus
    • Detecting the timing of asymptomatic estrus
    • Improving the effectiveness of artificial insemination
    • Improving the economic efficiency of farms
    ECI-500 Veterinary ovulation detector-detail 2
    ECI-500 Veterinary ovulation detector-detail 4
    Ovulation Detector Procedure
    • 1
      The animal's vulva was opened and a sterilized probe was carefully inserted into the vagina.
    • 2
      Taking care to insert the probe at a 45-degree angle from the bottom up to avoid inserting the probe into the urethra.
    • 3
      Ovulation detector is inserted further until resistance is felt such that the end of the probe with two electrodes is placed at the end of the animal's vagina, at the cervical canal. The probe is then rotated 1 turn to achieve optimal contact of the electrodes with the mucus. (Note: The depth of probe insertion depends on the length of the vagina and may vary from animal to animal, so insertion of the probe should always be followed until resistance is felt.)
    • 4
      Pressing the switch for measurement, press the switch once at an interval of 3 seconds, press three times for three measurements, and press the button again to display the measured value.
    • 5
      After measurement, long press the switch for shutdown or 30 seconds without operation automatically shutdown.
    ECI-500 Veterinary ovulation detector-detail 5 animal
    ECI-500 Veterinary ovulation detector-detail 6 application
    Frequently Asked Questions (FAQ)
    Q1: How does the ECI-500 Veterinary Ovulation Detector determine the timing of estrus?
    It measures the electrical resistance of the vaginal mucus. There is a close relationship between the changes in vaginal mucus resistance and the animal's hormone levels, allowing the device to determine the optimal timing for insemination.
    Q2: Why is the insertion angle of the probe critical during operation?
    The probe must be inserted at a 45-degree angle from the bottom up. This specific angle prevents the probe from accidentally entering the urethra, ensuring safe and correct placement in the vagina.
    Q3: How many times should I measure to get an accurate reading?
    It is recommended to press the switch once every 3 seconds for a total of three measurements. Pressing the button again after three cycles will display the finalized measured value.
    Q4: Are the probing rods adjustable for different types of livestock?
    The ECI-500 comes with specific probe sizes designated for different animals: 300mm for pigs, 200mm for sheep, 425mm for cows, and 120mm for dogs to match their anatomical structures.
    Q5: What materials are used for the probe to ensure animal safety?
    The probe is made of bio-silicone, which is safe, biocompatible, and easy to sterilize, while the main body is constructed from durable ABS material.
    Q6: Does the device have an automatic power-saving feature?
    Yes, the device will automatically shut down after 30 seconds of inactivity to preserve the 9V6F22 battery life. You can also manually shut it down by long-pressing the switch.